Yokogawa NFTC5S-00 CENTUM Series Datasheet & Technical ManualYokogawa NFTC5S 00 FIO Terminal Board Configured for field wiring routing in Yokogawa distributed control networks, the Yokogawa NFTC5S 00 (NFTC5S FIO Terminal Board) provides direct physical electrical execution. Suffix Breakdown & Model Matrix Base Model: NFTC5S (FIO Terminal Board Pressure Clamp Terminal Block) Suffix 00: Standard mechanical block configuration without integrated surge absorbers Style S2: Current hardware revision manufacturing
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Yokogawa NFTC5S-00 FIO Terminal Board

Configured for field wiring routing in Yokogawa distributed control networks, the Yokogawa NFTC5S-00 (NFTC5S FIO Terminal Board) provides direct physical/electrical execution.

Suffix Breakdown & Model Matrix

  • Base Model: NFTC5S (FIO Terminal Board / Pressure Clamp Terminal Block)
  • Suffix -00: Standard mechanical block configuration without integrated surge absorbers
  • Style S2: Current hardware revision manufacturing specification

Hardware Specifications

Parameter Specification
Model NFTC5S-00
Brand Yokogawa
Origin Japan
Weight 0.2 kg
Dimensions 44 mm x 102 mm x 108 mm
Operating Temp -20 to +55 deg C
Power Consumption Passive distribution block (0 mA)
Channel Capacity 32 discrete digital signal points
Maximum Voltage 600 VAC
Current Rating 5 A maximum continuous across bus common
Dielectric Strength 1500 VAC for 1 minute
Insulation Resistance Minimum 100 MOhm at 500 VDC
Wiring Method Pressure-clamp mechanism
Compatible Wire Size 2.0-2.6 mm2 (AWG 14-13)

Process Control & DCS Instrumentation Features

The terminal unit utilizes channel-to-channel isolation principles to decouple external loop wiring loops from sensitive backplane hardware layers. It integrates an interface layer optimized for 4-20 mA HART loop protocol routing and RTD/TC signal paths when paired with appropriate digital or analog FIO cards. The passive architecture provides separate instrumentation shield grounding networks to mitigate external high-frequency electrical noise and common-mode signal interference before it reaches the control processor environment.

Frequently Asked Questions

Q: Does the module contain internal transient voltage surge suppression?

A: No. The -00 suffix specifies a standard mechanical block configuration without surge absorbers. External suppression devices must be installed on inductive loop circuits to protect against back-EMF spikes.

Q: What is the maximum continuous current rating for the common bus lines?

A: The common bus architecture supports a maximum continuous current distribution threshold of 5 A. Loop loads exceeding this specification require external interposing relays.

Q: Can this component undergo live hot-swap insertion or removal during system operation?

A: Because it is a passive field wiring interface rather than an active module, physical detachment will immediately open all 32 field signal loops. Disconnection must only be performed when the associated field loop power is isolated.

Field Installation Guidelines

  • Mount the passive terminal block directly onto the corresponding Yokogawa I/O baseplate or terminal rack interface slots. Verify that all mechanical alignment guides seat completely before securing the module screws.
  • Execute field wiring terminations via the integrated M4 screw pressure-clamp mechanism. Strip wire insulation back to recommended depths and apply round crimp terminals rated for AWG 14-13 wire diameters.
  • Connect all instrument cable shields directly to the dedicated independent M4 ground terminal. Ensure this ground line runs directly to the marshaling cabinet master instrumentation ground bus.

Yokogawa NFTC5S-00 CENTUM Series Datasheet & Technical Manual

Item no : 10998175151
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 22 - Jun 27

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches