20% OFF shipping at pannenkoekenrestaurants.nl on orders over $79 + up to 10% OFF products
pannenkoekenrestaurants.nl
home > NFLR121-S00 Yokogawa Relay Output Unit | New & Original Stock > NFLR121-S00 Yokogawa Relay Output Unit | New & Original Stock
download picture
NFLR121-S00 Yokogawa Relay Output Unit | New & Original StockYokogawa NFLR121 S00 CENTUM VP CS 3000 FIO Subsystem The Yokogawa NFLR121 S00, also cataloged as the Yokogawa NFLR121 Relay Output Terminal Block Unit, operates as a dedicated hardware component for relay isolated output interface execution within CENTUM VP CS 3000 FIO platforms. Configured for high density physical signal switching, the device isolates digital logic control circuits from external physical field loads via electro mechanical contacts.
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Yokogawa NFLR121-S00 CENTUM VP/CS 3000 FIO Subsystem

The Yokogawa NFLR121-S00, also cataloged as the Yokogawa NFLR121 Relay Output Terminal Block Unit, operates as a dedicated hardware component for relay-isolated output interface execution within CENTUM VP / CS 3000 FIO platforms. Configured for high-density physical signal switching, the device isolates digital logic control circuits from external physical field loads via electro-mechanical contacts.

Suffix Breakdown & Model Matrix

Suffix / Identifier Code Description
Base Model NFLR121 Relay Output Terminal Block Unit
Protection Type -S00 Standard configuration without internal surge absorbers
Build Style Style S1 Standard production physical and trace layout variant

Hardware Specifications

Parameter Specification
Model NFLR121-S00
Brand Yokogawa
Origin Japan
Weight 0.25 kg
Dimensions 114 x 32.6 x 60.5 mm
Operating Temp -20 to +55 deg C
Power Consumption Passive coil drive (24 VDC nominal loop derived)
Channel Capacity 32 discrete output points (Form A contacts)
Maximum Switching Voltage 250 VAC / VDC
Rated Contact Current 2 A maximum per channel
Dielectric Strength 1500 VAC for 1 minute (relay contacts to internal system logic)
Insulation Resistance 100 Mohm or greater at 500 VDC
Wiring Terminal Type Pressure-clamp M4 screw terminal blocks

4-20 mA HART Loop Protocol & Channel Isolation

While handling digital command verification, this instrumentation architecture integrates with platforms processing adjacent 4-20 mA HART loop protocol signals. The unit relies on galvanic physical separation to prevent loop noise migration across the terminal plane. Internal layout properties deliver high channel-to-channel isolation parameters, checking crosstalk issues and ensuring that high-voltage inductive switching transients do not disrupt analog data integrity or sensor feedback loops sharing the local control enclosure.

Frequently Asked Questions

Q: Does the -S00 suffix version provide protection against inductive field spikes?

A: No. The -S00 suffix designates a standard layout configuration lacking built-in surge absorbers. Inductive external loads such as large solenoids or motor starters require localized diode snubber circuits or external RC networks across the field wiring terminals to safeguard the internal electromechanical relay contacts.

Q: Can the pressure-clamp terminals accept direct stranded wiring layouts without ferrules?

A: Yes. The pressure-clamp structure supports round crimp terminals with M4 screws, accepting wire dimensions from 0.5 to 2.5 mm2 (AWG 20 to 14). However, using crimped ferrules prevents strand separation and preserves electrical connection reliability under low-frequency industrial vibration conditions.

Field Installation Guidelines

  • Secure the physical chassis directly onto the FIO baseplate using the manufacturer-specified terminal mounting tracks to ensure correct bus alignment.
  • Maintain strict structural separation between external high-voltage AC load lines and low-voltage DC communication or I/O module wires inside the cable duct system.
  • Ensure all terminal screws match the specific torque limits for AWG 20-14 wiring interfaces to stop localized overheating or physical terminal fracturing.
  • Connect the dedicated shield/earth terminal terminal explicitly to the local technical plant ground bus to stabilize baseline reference potentials.

NFLR121-S00 Yokogawa Relay Output Unit | New & Original Stock

Item no : 19150349115
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 22 - Jun 27

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

UPLIFT
UPLIFT

US$ 126.75

Min. order: 1 piece

4.1 (139 reviews)

Sold : Login>>

Related Searches