20% OFF shipping at pannenkoekenrestaurants.nl on orders over $79 + up to 10% OFF products
pannenkoekenrestaurants.nl
home > ProSoft MVI46-MCMSLC 500 Series Datasheet & Technical Manual > ProSoft MVI46-MCMSLC 500 Series Datasheet & Technical Manual
download picture
ProSoft MVI46-MCMSLC 500 Series Datasheet & Technical ManualProSoft MVI46 MCM SLC Modbus Communication Module The ProSoft MVI46 MCM, also cataloged as the MVI46MCM Modbus Master Slave Interface Module, operates as a dedicated hardware component for asynchronous serial data conversion within Allen Bradley SLC 500 platforms. Hardware Specifications Parameter Specification Model MVI46 MCM (Spare Model: MVI46MCM 1700095) Brand ProSoft Technology (Belden ProSoft) Origin United States Weight 0. 22 kg (0. 50 lbs)
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

ProSoft MVI46-MCM SLC Modbus Communication Module

The ProSoft MVI46-MCM, also cataloged as the MVI46MCM Modbus Master/Slave Interface Module, operates as a dedicated hardware component for asynchronous serial data conversion within Allen-Bradley SLC 500 platforms.

Hardware Specifications

Parameter Specification
Model MVI46-MCM (Spare Model: MVI46MCM 1700095)
Brand ProSoft Technology (Belden ProSoft)
Origin United States
Weight 0.22 kg (0.50 lbs)
Dimensions 2.5 cm x 15.2 cm x 12.7 cm (1.0 in x 6.0 in x 5.0 in)
Operating Temp 0 deg C to 60 deg C (32 deg F to 140 deg F)
Storage Temp -40 deg C to 85 deg C (-40 deg F to 185 deg F)
Relative Humidity 5% to 95% (non-condensing)
Vibration Resistance 5 g from 10 to 150 Hz
Slot Occupancy Single-slot module
Compatible Rack 1746 chassis
Backplane Current Load 800 mA @ 5 VDC (also rated up to 5.1 VDC)
Data Memory Size 5000-word register space

Protocol Conversion Latencies & Backplane Arbitration

The module functions as a local input/output card interface between the Modbus serial network topology and the Rockwell Automation 1746 backplane. Data allocation within the hardware architecture uses an integrated 5000-word register memory segment to hold data values transferred between the foreign devices and the SLC processor.

The physical transmission of bits across the serial network link runs asynchronously from the backplane transfer cycle. This dual-port decoupling controls protocol conversion latencies, protecting the main SLC ladder program scan time from network polling delays. The configuration supports both Modbus Master and Modbus Slave roles to manage foreign data concentrator functions.

Frequently Asked Questions

Q: Does the MVI46-MCM module support hot-swapping or Remove and Insert Under Power (RIUP) actions within the 1746 rack? A: No. The 1746 chassis and backplane architecture do not permit online component extraction. System power must be isolated before sliding the module into or out of the slot to prevent physical circuit breakdown or hardware failure.

Q: How is data synchronized between the module's 5000-word register space and the SLC processor? A: Data routing uses M0 and M1 files driven by the SLC logic application. Because the memory block exchange runs asynchronously to the serial protocol loop, user logic handles the data block pagination without stalling the network transmission lines.

Q: What is the maximum current load drawn from the 1746 chassis power supply? A: The module demands 800 mA directly from the 5 VDC (up to 5.1 VDC) internal backplane rail. This current draw must be factored into the overall power budget calculations of the local 1746 power supply unit.

Field Installation Guidelines

  • Chassis Insertion Restrictions: De-energize the 1746 chassis fully. Align the printed circuit board card guides into the target slot tracks of the rack and apply even pressure until the top and bottom plastic retaining tabs snap lock into place.
  • Serial Wiring Shielding: Route all serial communication lines through dedicated low-voltage wire conduits. Use high-quality shielded twisted-pair cables, and ensure the drain wire terminates at a single low-impedance grounding bar within the control panel to block industrial electromagnetic interference (EMI).
  • Line Termination Requirements: For long physical cable runs or configurations experiencing high signal reflection, connect a 120-ohm matching end-of-line resistor across the differential RX/TX lines on the termination blocks of the final network nodes.

ProSoft MVI46-MCMSLC 500 Series Datasheet & Technical Manual

Item no : 86580335951
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 21 - Jun 26

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches